MIL-PRF-32517
TABLE VI. Qualification inspections Continued.
Requirement
Test method
Examination or test
paragraph
paragraph
Group VI (2 matched impedance splice assemblies) 1/
Flammability
3.4.14
4.6.11
Group VII (6 matched impedance splice assemblies) 1/
3.4.10
4.6.6.2
Fluid immersion
3.4.9
4.6.6.1
Altitude immersion (1 cycle)
3.4.5
4.6.7
Insulation resistance
3.4.6
4.6.8.2
Dielectric withstanding voltage (Wet)
1/ The matched impedance splice assemblies shall be installed on MIL-DTL-17 cables with
cable leads at least 5 feet in length (10 feet total length). See 4.2.2.
2/ Group sequence not required (two separate specimens).
3/ Qualifying activity test groups