MIL-PRF-32517
4.3.2 Qualification inspection samples. Matched impedance splices shall be assembled
as specified in 4.2.2 for testing and submitted to the qualifying activity as follows:
a. For the qualifying activity tests, 25 unwired specimens (19 for testing and 6
spares) for each part number shall be separately packaged and forwarded to the address (see 6.3)
designated in the letter of authorization. Sufficient cables conforming to MIL-DTL-17 shall be
provided to perform the designated tests. Each sample shall be identified by marking each
package with the following information: Sample for qualification
Specification MIL-PRF-32517
Part number ____________________
SPLICE, CONDUCTOR, ELECTRICAL, COAXIAL CABLE, MATCHED
IMPEDANCE
Name of supplier
Supplier's part number
Submitted (date) under authorization (reference letter authorizing the inspection)
b. For the supplier tests, 25 specimens shall be tested in accordance with table VI for
each part number.
4.3.3 Retention of qualification. Retention of qualification inspections shall be
performed every 36 months after the original qualification approval date. The qualifying activity
shall perform or witness the tests specified in table VII. Unless otherwise specified in table VII,
sequential testing is required for each group. The qualifying activity may shift the reporting date
to accommodate testing schedules, but no later than 18 months from the retention of qualification
due date.
4.3.3.1 No production certification. If no production of the qualified products has
occurred for the entire reporting period, the supplier shall provide certification to the qualifying
activity that no changes in the product materials, design, manufacturing processes, or site of
production have occurred since qualification approval (see 4.3). Certification for more than one
reporting period is not permitted. The supplier shall contact the qualifying activity to determine
the conditions for certification. The supplier shall submit the certification on DD Form 1718
provided by the qualifying activity.